<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-07 01-11-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 35 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 9 kHz 14261 0,1683
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,67 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:11, 7.06.2024
RT
"Jak to vidi... - Vyvoj mezd a nerovnosti v prijmech ruznych p..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 9 kHz MIN: 7 kHz % above 77 kHz: 0,1683 Acquired: 2024/06/07 1:11:55 Total samples: 14261 Equivalent time: 0:11:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300